AM 150

AM 150 is the smallest Airmaster decentralised ventilation unit, with heat recovery. AM 150 is designed especially for small rooms such as offices seating one or two people, as well as small meeting rooms and group rooms.

With AM 150, you get a unit that is particularly suitable for 1–2-people offices and small group rooms in offices, at schools or at institutions. In short: small rooms where a comfortable indoor climate is required, contributing to comfort and well-being.

AM 150 is a horizontal wall/ceiling-mounted unit, with the supply and exhaust at the rear. The ventilation unit is produced to the same high quality as Airmaster’s other products, using quality components, EC energy-saving motors, a countercurrent heat exchanger, etc.

With options such as motion sensors and CO2 sensors, it is possible to demand-control the ventilation unit according to how many people are in the room at a given time. The fully automatic control can also be combined with Airmaster Airlinq® Online.

Offering the option of installing the AM 150 on the wall or on a ceiling frame, it is also an obvious choice for modular buildings. It can be fully visible, or you can choose to partially integrate it into the ceiling so that only the lower section is visible. It is possible to pipe the exhaust, making it possible to install the ventilation unit above a diffuse ceiling, or connect the exhaust from an adjoining room.

Examples of applications

  • 1–2-person offices
  • Small meeting rooms and the like
  • Modular buildings
  • Hotel rooms
Data AM 150

TECHNICAL DATA

Filter class

30 dB(A)

35 dB(A)

Boost

Maximum capacity

ePM10 75%

ePM1 55%

ePM1 80%

115 m3/h

90 m3/h

85 m3/h

147 m3/h

126 m3/h

115 m3/h

216 m3/h

197 m3/h

180 m3/h

Throw length (0.2 m/s)

ePM10 75%

ePM1 55%

ePM1 80%

2,6 m at 115 m3/h

2,1 m at 90 m3/h

1,9 m at 85 m3/h

3,4 m at 147 m³/h

2,8 m at 126 m³/h

2,6 m at 115 m³/h

-

-

-

Nominal current*

0,2 A

0,3 A

1 A

Nominal power consumption*

21 W

38 W

96 W

Electrical connection

1 x 230 V + N + PE / 50 Hz

Duct connections

Ø125 mm

Weight

47 kg

Counterflow heat exchanger

PET

Supply air filter

ePM10 75%, ePM1 55% or ePM1 80%

Extract air filter

ePM10 75%

Colour, panel

RAL 9010 (white)

Power cable

3 x 0,75 mm²

Recommended fuse

10 A

Leakage current

<– 0,5 mA

Energy class (SEC-class)

A

Air leakage classification

Class L1 cf. EN 1886:2007

Class A1 cf. EN 13141-7:2010

Dimensions (WxHxD)

1170 x 261 x 572 mm

* At filter class, supply air/extract air: ePM10 75% / ePM10 75%

ELECTRIC HEATING SURFACE

Heat output

600 W

Thermal circuit breaker, aut. reset

75°C

Thermal circuit breaker, man. reset

90°C

Standard and options

Standard and options

AM 150 H

Bypass

x

Electric heating surface/VPH

CO2 sensor (built-in)

PIR/motion sensor (built-in)

Condensate pump

Motor driven exhaust air damper

x

Motor driven supply air damper

x

Counterflow heat exchanger (PET)

x

Energy meter

Wall / Ceiling frame

x: standard
: option

Throw lenth

The ventilation unit diffuses the supply air to varying degrees depending on the slat settings. This is shown in the illustrations, which indicate the diffusion pattern and throw at the different slat settings.
The airflow also influences the throw.

Throw length, side view

Throw length, top view

Throw length at 0,2 m/s. The supply pattern is shown in different settings at 147 m3/h.

1. Throw length with 60º blade angle.
2. Throw length with 45º blade angle. (Small inlet diffusor)
3. Throw length with 30º blade angle
.

Ready for a breath of fresh air

At Airmaster, we are “decentral” through and through. We are unrivalled when it comes to creating the best indoor climate and optimal well-being because we take each room and its occupants into account – and because we constantly strive to improve on what we do.

Newsletter